Aama 501.2 pdf تنزيل

`Comparison of the AAMA/WDMA/CSA 101/I.S.2/A440 -08 lab test (referred to as NAFS-08) to the AAMA 502 quality assurance field test and the AAMA 511 forensic evaluation `Determination of appropriate water test pressures, test durations and water applications via NAFS-08, AAMA 502-08, 503-08 and 511-08 `How to specify project-specific quality

1.2 Consensus Document – AAMA 502 has been created by the American Architectural Manufacturers Association (AAMA), which is an industry association. People from various aspects of the industry (manufacturers, architects, test labs, etc.) are involved in the association, and have say on the content of the document. AAMA 502 references other

The AAMA 501.2 test is a Quality Assurance and Diagnostic Water Leakage Field Check of Installed Storefronts, Curtain Walls, and Sloped Glazing Systems. What  

AAMA 502. However, it is not appropriate for testing operable doors and windows, does not sim - ulate the effects of wind-driven rain and provides no quantitative results that can be compared to the product’s design pressure or performance grade. In many cases, erroneous use of AAMA 501.2 or inappropriate adaptations of AAMA 502 have Mar 23, 2020 · aama-501.2-03-fieldcheckwater-hosetest.pdf A project architect or another representative specifier will select the area to be tested. If no leaks occur, the area stays uncovered, and the test goes on. AAMA 501.1­05, Standard Test Method for Water Penetration of Windows, Curtain Walls, and Doors Using Dynamic Pressure. Testing was conducted with a dynamic pressure equivalent of 300 Pa (6.2 psf) for a 15 minute duration. Water was applied to the mock‐up at a minimum rate of 5 gal/hr/ft2. AAMA 501.2 Quality Assurance and Diagnostic Water Leakage Field Check of Installed Storefronts, Curtain Walls, and Sloped Glazing Systems AAMA 502 Voluntary Specifications for Field Testing of Windows and Sliding Glass Doors AAMA 511 Voluntary Guideline for Forensic Water Penetration Testing of Fenestration Products RILEM Test Method 11.4 RILEM The procedure outlined in this document is not intended to test the rated or specified water performance representative of a wind driven rain event. AAMA 503 is the proper test method for field testing of storefronts, curtain walls, and slope glazing for air leakage resistance and water penetration resistance performance. (AAMA 501.2-03) Jun 20, 2018 · The AAMA 501.2 standard is designed to test the water tightness of large glass areas that are permanently sealed. These areas usually include storefronts, curtain walls, and sloped glazing systems. The entire principle behind the spray nozzle water leak testing is to identify issues with the installation of the glass area. Apr 08, 2020 · AAMA 502 08 PDF - most recent revision of the AAMA and. field testing protocols. AAMA 08,. "Voluntary Specification for Field Testing of. Newly Installed Fenestration.

1.2 Consensus Document – AAMA 502 has been created by the American Architectural Manufacturers Association (AAMA), which is an industry association. People from various aspects of the industry (manufacturers, architects, test labs, etc.) are involved in the association, and have say on the content of the document. AAMA 502 references other May 03, 2020 (AAMA 501-05 and ASTM E330-02) +1436/-1436 Pa (+30/-30 psf) Design Wind Load PASS . 3.3 Test Record Retention End Date: All test records for this report will be retained until October 26, 2016. 4.0 APPLICABLE TEST METHODS, SPECIFICATIONS, AND PROTOCOLS . AAMA 501-05 – Methods of Tests for Exterior Walls buy aama 501.1 : 2017 standard test method for water penetration of windows, curtain walls and doors using dynamic pressure from sai global The Rain Wand comes with a dated calibration certificate in compliance with the AAMA 501.2 test standard. The Monarch B-25 nozzle provides a solid cone spray at an angle of 80 degrees. Comes in a padded carrying case; This is the only way to adhere correctly to the AAMA 501.2 standard for testing curtain walls and storefront windows in the field.

determined in accordance with AAMA 501.6 or through engineering analysis. Both test methods are routinely specified by architects. AAMA 501.4-09 is a static racking test method concerned with the serviceability of curtain wall and storefront glazing systems following a seismic event. This method requires companion air AAMA and IGMA, two industry leaders, have unified to form an exponentially stronger alliance. Designed to help our members excel in a dynamic and fast-moving future, the Fenestration and Glazing Industry Alliance, or FGIA, is focused on building better industry synergies from glass to framing. Standard: AAMA 501.2-15 – Quality Assurance and Diagnostic Water Leakage Field Check of Installed Storefronts, Curtain Walls, and Sloped Glazing Systems Scope : This test is utilized to provide quality assurance and diagnostic field water penetration check method for installed storefronts, curtain walls and sloped glazing systems. AAMA 501.2-03 PDF - A M E R I C A N A R C H I T E C T U R A L AAMA Quality Assurance and Diagnostic Water Leakage Field Check of Installed. AAMA Test Method Field testing by buy aama 501.2 : 2015 quality assurance and diagnostic water leakage field check of installed storefronts, curtain walls and sloped glazing systems from sai global AAMA 501.2: Quality Assurance and Diagnostic Water Leakage Field Check of Installed Storefronts, Curtain Walls and Sloped Glazing Systems A water spray quality check to reveal leaks in non-operable glazing systems that includes gaskets, sealants, perimeter caulking, splices and frame joinery intersections. Field Window Test Types

AAMA 501.2 Quality Assurance and Diagnostic Water Leakage Field Check of Installed Storefronts, Curtain Walls, and Sloped Glazing Systems CAN/CGSB 149-GP-2MP Manual for ThermographicAnalysis of Building Enclosures

The procedure outlined in this document is not intended to test the rated or specified water performance representative of a wind driven rain event. AAMA 503 is the proper test method for field testing of storefronts, curtain walls, and slope glazing for air leakage resistance and water penetration resistance performance. (AAMA 501.2-03) Interpret AAMA 2603, 2604 & 2605 performance requirements for organic finishes, for use in specs Apply the concepts of air, water, structural and life-cycle testing to knowledge about building integrity, soundness and energy efficiency (HSW) AAMA/WDMA/CSA 101/I.S.2/A440-08 AAMA 501.1­05, Standard Test Method for Water Penetration of Windows, Curtain Walls, and Doors Using Dynamic Pressure. Testing was conducted with a dynamic pressure equivalent of 300 Pa (6.2 psf) for a 15 minute duration. Water was applied to the mock‐up at a minimum rate of 5 gal/hr/ft2. AAMA and IGMA, two industry leaders, have unified to form an exponentially stronger alliance. Designed to help our members excel in a dynamic and fast-moving future, the Fenestration and Glazing Industry Alliance, or FGIA, is focused on building better industry synergies from glass to framing. AAMA 501.2 Quality Assurance and Diagnostic Water Leakage Field Check of Installed Storefronts, Curtain Walls, and Sloped Glazing Systems AAMA 502 Voluntary Specifications for Field Testing of Windows and Sliding Glass Doors AAMA 511 Voluntary Guideline for Forensic Water Penetration Testing of Fenestration Products RILEM Test Method 11.4 RILEM


AAMA 501.2-15: Quality Assurance and Water Field Check of Installed Storefronts, Curtain Walls and Sloped Glazing Systems. Standard: AAMA 501.2-15 – Quality Assurance and Diagnostic Water Leakage Field Check of Installed Storefronts, Curtain Walls, and Sloped Glazing Systems. Scope: This test is utilized to provide quality assurance and diagnostic field water penetration check method for

Leave a Reply